Weight:
4.00 KGS
Shipping:
Calculated at Checkout
₦0.00

Description

AM-10 Patient Monitor (10.1 inch)

Features

  1. 10.1-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
  2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
  3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
  4. SPO2 can testing for 0.1% Weak;
  5. RA-LL impedance Respiration;
  6. Trend Coexist Display;
  7. OxyCRG DyNamic View Display;
  8. Bed to Bed view Display;
  9. Networking capacity and nurse calling system;

10. Options of IBP, EtCO2, Central Monitoring System;

11. Built-in rechargeable battery 4400mAh;

12. 10.1" high resolution color TFT LCD display;

13. Large volume of tabular and graphic trends information storage and easy to recall;

14. Anti-ESU, anti- defibrillator;

15. Capture dynamic waveforms.

Technical Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1 ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

Heart Rate and Alarm

Range

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great

Resolution: 1 bpm

Sensitivity: > 200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR

-Monitor: > 105 dB

-Operation: > 105 dB

-Diagnosis: > 85 dB

Electrode offset potential: ±300mV

Leakage Current: < 10 uA

Baseline Recovery: < 3 S after Defi.

ECG Signal Range: ±8 m V (Vp-p)

Bandwidth  

-Surgery: 1 ~ 15 Hz

-Monitor: 0.5 ~ 35 Hz

-Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5% 

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available

Respiration

Method: Impedance between R-F (RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range: 0.3~5.0Ω

Base line Impedance Range: 0 – 2.5 KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range

-Adult: 0 ~ 120 rpm

-Neo/Ped: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy: ±2 rpm

Apnea Alarm: 10 ~ 40 S

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range

Contact us for further details and availability within  your location.

View AllClose

1 Review

  • 5

    Excellent

    Posted by Robert on Oct 16, 2019

    Very portable and lovely

View AllClose