Description
Anesthesia Machine AR-325 ARI
GZ Industrial Supplies is the Distributor and Supplier of ARI Medical Equipment in Nigeria. This Anesthesia Machine AR-325 ARI is a medical device used to generate and mix a fresh gas flow of medical gases and inhalational anaesthetic agents for the purpose of inducing and maintaining anaesthesia. It is used to deliver general anesthesia to patients as they undergo a medical procedure. The most commonly used device is the continuous-flow anesthetic machine, which provides a steady flow of air containing a regulated supply of gas. Modern instruments often include monitors and touch-screen displays that provide data on heart rate and oxygen saturation level.
The basic anesthetic delivery system consists of a source of oxygen (O2), an O2 flowmeter, a precision vaporizer, which produces a vapor from a volatile liquid anesthetic, a patient breathing circuit (tubing, connectors and valves), and a scavenging device that removes any excess anesthetic gases. This is critical, since room pollution with anesthetic gases may lead to health problems in animals as well as in humans.
During delivery of gas anesthesia to the patient, O2 flows through the vaporizer and picks up the anesthetic vapors. The O2-anesthetic mix then flows through the breathing circuit and into the patient's lungs, usually by spontaneous ventilation (respiration). Occasionally, it is necessary to use assisted ventilation, especially when opening the chest (thoracic) cavity. Assisted ventilation is accomplished by use of a ventilator or respirator.
Technical Specifications of Anesthesia Machine AR-325 ARI
PARAMETER |
SPECIFICATION |
Main Body |
High-strength engineering plastic rack, light, beautiful and corrosion resistant |
Scope of Application |
Adult, child |
Gas Source |
O2: 0.27--0.55Mpa; N2O: 0.27--0.55MPa. |
Flow Meter |
O2: 0.1--1.0L/min; 1.1--10L/min N20: 0.1--1.0L/min; 1.1--10L/min Air: 0.1--10L/min |
O2, N2O Linkage and N2O Stopper |
When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure < 0.2KPa, the flow of nitrous oxide would be cut off. |
Flow Rate of Rapid Oxygen Supply |
25--75L/min |
Low Oxygen Pressure Alarm |
There will be sound alarm when the oxygen pressure < 0.2MPa |
Vaporizer |
It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0-5vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available. |
Respiratory Circuit |
Working mode: all-close, semi-close, semi-open; APL: 0.5-7kPa |
Respiratory Bellows |
Bellows for adults, tidal volume range:0--1500ml; Bellows for children, tidal volume range:0-300ml. Anyone can be chosen for application as required by the customer |
VENTILATOR |
|
Display Mode |
10.4” Touch Screen, High-definition TFT color LCD |
Ventilation Mode |
IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH, IMV, VCV, PCV |
Ventilation Parameters |
Tidal volume 20--1500ml Rate 1--99bpm SIMV rate 2--20bpm I:E 4:1--1:8 Inspiratory trigger pressure -1.0--2.0kPa PEEP 0--2.0kPa Pressure range 1.0--6.0kPa SIGH 1.5 times the inspiratory time, 70-150 adjustable Inspiratory platform 0--50% |
Parameters for Ventilation Monitoring |
Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure – time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform, autonomous inspiratory rate, lung compliance, airway resistance, flow-volume loop, pressure-volume loop |
Monitoring of Oxygen Concentration |
21%--100% |
SECURITY ALARM SYSTEM |
|
Oxygen Concentration Alarm |
Upper limit setting range 21%--100%; Low limit setting range 10%--80% |
Airway Pressure Alarm |
Upper limit setting range 0.3--6.0 kPa; Low limit setting range 0.2--5.0 kPa. |
Per-minute Ventilation Volume Alarm |
Upper limit setting range 3.0--30L/min; Low limit setting range 1.0--10L/min. |
Sustained High-pressure Alarm |
It will give alarm when stress have consistently been higher than 2.5 kPa |
Suffocation Alarm |
It will give sound and light alarm if there is no tidal volume input for 15 seconds |
POWER ALARM |
|
Power |
AC 220V±10%, 50Hz±1Hz, Storage battery (UPS) |
Mechanical Arms (End-expiratory CO2 monitoring) |
|
Note: Items within brackets are optional. |
Contact us we have products available in all our stores nationwide.
1 Review
-
well designed
The indication system when gases levels are low or high works well. I must say I'm very impressed with this machine.