Features:

1. Simplified, Intuitive Touch

- Independent operating channels, and with Online function----AB channels can be worked cyclically and repeatedly;

- 3.5-inch large color display, making clinical use faster and more convenient;

- Independent power switch, conducive to clinical use and energy conservation;

-Tube management: a standard fitted side clamp to prevent infusion tube entanglement and enhance infusion overview and control. 

2. Safe, Efficient and Practical

- Comply with IP44 high waterproof rating for all clinical application scenarios;

- DPS dynamic pressure display, multi-pressure alarm level, real-time protection of patient safety;

- Anti-bolus & anti-siphon functions increase patient safety;

- Auto & manual Bolus can be switched; KVO rate is adjustable for more clinical use;

- Change the flow rate during infusion without stooping the infusion;

- Large-scale & wide-angle color alarm lights to protect patients in real time.

3. Intelligent Design, Easy to Use

 - 5 infusion modes are available to meet the needs of different departments;

- 360 degree rotatable, vertical and horizontal mounting clamp to meet the needs of the clinical environment;

- More than 2,000 historical records for review and export, which is convenient for users to use;

- Multi-language can be switched and customized to meet various geographical needs.

Technical Specifications

PARAMETER

SPECIFICATION

Applicable Syringes

5ml,10ml,20ml,30ml,50ml,60ml of any standard

Accuracy

+/- 2% with correct calibration

Rate Mode

50ml(60ml): 0.1ml/h-2000.0ml/h (0.1ml/h or 1ml/h step)

30ml: 0.1ml/h-1200.0ml/h (0.1ml/h or 1ml/h step)

20ml: 0.1ml/h-800.0ml/h (0.1ml/h or 1ml/h step)

10ml: 0.1ml/h-400.0ml/h (0.1ml/h or 1ml/h step)

5ml: 0.1~200ml/h (0.1ml/h or 1ml/h step)

(Programmable 0.01ml/h~9999.9ml/h)

Time Mode

SOL. VOL: 0.1-9999.9ml (0.1ml step)

TIME: 00:01-99:59min (1min step)

Dose Mode

Volume: 0.1-999.9ml (0.1ml step)

DRUG MASS: 0.1-999.9mg (0.1mg step)

DOSE: 0.001-9999ug/kg/min (0.001ug/kg/min step)

WEIGHT: 0.1-300kg (0.1kg the least step)

Dose unit: ng/kg/min, ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h,

mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, U/h,

IU/h, U/kg/h, ml/h

Total Volume Range

0.1-9999.9ml (0.1 ml step)

Drug library Mode

10 categories of drugs, 17kinds of dose units.

Makes drug dispensing more convenient and safer.

Sequential Mode

Available

Purge Rate

50ml(60ml): 1500.0ml/h,

30ml: 1200.0ml/h,

20ml: 800.0ml/h

10ml: 400.0ml/h, 5ml: 200ml/h

Programmable and adjustable

KVO Rate

0.1~5.0 ml/h, Programmable and adjustable

DPS Dynamic Pressure

Three levels setting LOW (60(±15)kPa), MEDIUM (90(±15)kPa) or HIGH (120(±15) kPa)

Alarms

Syringe Holder Loose, Syringe Plunger Disengagement, Syringe

Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe

Empty, Rate Abnormal, Battery Empty, No Battery, Infusion

Complete, Syringe Near Empty, No Action, Battery Low

Three levels of alarm volume LOW, MEDIUM or HIGH

Bolus Rate

5ml: 0.1~200ml/h,10ml:0.1-400ml/h,20ml:0.1-800ml/h,

30ml: 0.1-1200ml/h,50ml(60ml):0.1-2000ml/h

Programmable and adjustable, Automatic/Manual bolus available

Bolus Volume

Range: 1.0~50.0ml, (0.1ml step)

Interface

RS-232

Brightness

1~10 levels can be selected

History Records

2000 events stored can be checked and downloaded

Power Source

AC power supply: AC 100 to 240V(+/-10%), 50/60Hz;

DC Power supply: 12~15V, power>15W;

Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh.

8 hours of continuous operation

Accessories

AC power line, Operational manual

Protection Class

Class I, Type CF, IP44

Dimension/N.W

350*150*220mm, 4kg

Packing size/G.W

400mm*200mm*2500mm, 4.5KG