CMS5100 Patient Monitor NIBP,SPO2,PR Contec

(1 review) Write a Review
SKU:
CONTEC CMS5100
UPC:
658126881654
MPN:
CONTEC CMS5100
Weight:
1.60 KGS
Shipping:
Calculated at Checkout
₦0.00

Description

CMS5100 Patient Monitor NIBP,SPO2,PR Contec

GZ Industrial Supplies Nigeria Supplies a wide range of Medical supplies and equipment which form an increasingly important element of a healthcare professional’s role. Our CMS5100 Patient Monitor NIBP,SPO2,PR Contec adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. The CMS5100 Patient Monitor Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR) can be accurately measured.The CMS5100 Patient Monitor NIBP,SPO2,PR Contec Compact appearance, comprehensive functions, simple and convenient operation,  is applicable for hospitals, community medical treatment and family.

Features of CMS51OO Patient Monitor NIBP,SPO2,PR Contec

Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.

■Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.

■Built-in rechargeable Li-polymer battery for uninterrupted monitoring.

■Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.

■With user-friendly interface.

■Display with 2.8'' (320×240) color TFT LCD and red and yellow highlight LED.

■Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.

■Unique Flash memory, storage for up to 2000 NIBP data and 78000 SpO2 data.

■Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.

Performance of CMS 5100 patient monitor NIBP,SPO2,PR Contec

 NIBP

  • Using Oscillometry technology, also called Oscillography technology to measure the blood pressure.
  • Measurement mode: manual/auto/continuous
  • Measurement interval in auto mode: 1, 2, 3, 4, 5, 5×n(n=2, 3, 4...51) min.
  • Resolution: 1 mmHg
  • Accuracy: max mean error: ±5 mmHg; max standard deviation: 8 mmHg.
  • Overpressure protection: dual protection for both software and hardware
  • Others: reset, self-testing and accuracy testing of static pressure
  • Measurement range:


Adult
SYS 40 mmHg~270 mmHg
MAP 20 mmHg~235 mmHg
DIA 10 mmHg~215 mmHg
Pediatric:
SYS 40 mmHg~200 mmHg
MAP 20 mmHg~165 mmHg
DIA 10 mmHg~150 mmHg
Neonate:
SYS 40 mmHg~135 mmHg
MAP 20 mmHg~110 mmHg
DIA 10 mmHg~100 mmHg


 SPO2
Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the saturation of blood oxygen.

  • Measurement range: 0 %~100 %

  • Alarm range: 0 %~100 %

  • Resolution: 1 %

  • Accuracy: 70 %~100 %, ±2 %; below 70 % unspecified.

PR
Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the pulse rate.

  • Measurement range: 25 bpm~250 bpm
  •  Alarm range: 25 bpm~250 bpm
  •  Resolution: 1 bpm
  •  Accuracy: ±2 bpm or ±2 %, whichever is greater Safety and Power supply

a)Power supply: rated voltage: ~220 V, rated power: 50 Hz
b)Safety classification: Class I equipment, type BF defibrillation-proof applied part

Physical Characteristic of CMS 5100 Patient Monitor NIBP, SPO2,PR Contec

Dimension: 190 mm(L)×162 mm(W)×240 mm(H)
Weight: about 1.6 kg

 

Accessories for CMS5100 Patient Monitor NIBP,SPO2,PR Contec
  • User Manual 1pc
  • Power cord 1pc
  • Power adapter 1pc
  • SpO2 sensor 1pc
  • Adult NIBP cuff 1pc
  • NIBP extension tube 1pc