TLC9803 Dynamic ECG Systems Digital 3-lead 24-hour Analyzer Contec
GZ Industrial Supplies Nigeria Supplies a wide range of Medical supplies and equipment which form an increasingly important element of a healthcare professional’s role. Our TLC Dynamic ECG Systems adopt 3-lead 24hour Analyzer Contec can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software.The TLC Dynamic ECG Systems adopt 3-lead 24hour Analyzer Contec is applicable for use in medical institution and community.
Function
1)The recorder can real-time store ECG data for 24-hour.
2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
4)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
5)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
6)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
7)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
8)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
9)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
10)One-key print, convenient and fast to print the reports.
11)Perfect case management function.
12)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
13)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
14)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death
Performance
Lead: 3-lead
Record time: 24-hour
Power supply: two “AA” batteries
Interface: USB2.0
Calibration voltage: 1mV±5%
Noise level: ≤30μV
CMRR: ≥60dB
Low-frequency characteristics: time constant≥3.2s
Scan speed: 25mm/s±5%
Polarizing voltage: ±300mV, sensitivity: ≤±10%
Minimum measure signal: 50 µV p-p
Physical characteristic
Dimension: 111mm(L) × 60mm(W) × 25mm(H)
Weight: about 105g(without batteries)